Common array manager.

Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest.

Common array manager. Things To Know About Common array manager.

1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet n.n.n.n. 3. After logging in, switch user …This URL seems to be what you want: Installing the Typical Full Management Software. But having said that - you may want to look at a newer and more …The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.0: Enhancements to Auto Service Request (ASR) functionality. Support for Sun StorageTek FLX240, FLX280, and FLX380 Arrays.Sun Storage Common Array Manager (CAM): How to Upgrade Firmware for Sun Storage 2500, 2500-M2, 6000 Arrays, J4000 JBODs, and F5100 Flash Arrays. (Doc …Common Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.

Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed. Sun Storage Flexline 380 Array Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: 5.0 and later] Sun Storage 6180 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Storage 6780 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A]

Sun Storage Common Array Manager (CAM) - Version 5.0 to 5.1 [Release 5.0] Oracle Solaris on SPARC (64-bit) Oracle Solaris on SPARC (32-bit) Oracle Solaris on x86-64 (64-bit) Oracle Solaris on x86 (32-bit) Symptoms. Execution of the RunMe.bin installer, or RunMe.bin -c, on Solaris[TM] Operating System, fails with: Instructions to download Common Array Manager (CAM). Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download. Click on "Search".

Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a …Jun 12, 2019 · This article documents Sun StorageTek Flexline 380 (FLX380) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of ... Sun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version …Overview of the Installation Process. Before you install the Common Array Manager software, you must do the following: Read the Sun StorageTek Common Array Manager Software Release Notes for any late-breaking information related to the installation of the array.; Install the array hardware per the hardware installation documentation that came …

These Common Array Manager 6.0.1 Release Notes describe new features, known issues, patches and installation notes, and provide the most current product information. Sun StorageTek Common Array Manager Software Release Notes, Release 6.0.1 ...

Sun Storage Common Array Manager (CAM): How to Upgrade Firmware for Sun Storage 2500, 2500-M2, 6000 Arrays, J4000 JBODs, and F5100 Flash Arrays. (Doc …The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring.The purpose of this document is to describe how to collect logs and configuration data from the machine running Sun Storage Common Array Manager version 6.0 or later. The command will collect the configuration database and all relevant log files for support and troubleshooting. If you need to collect a support data from the array, please …Common Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.

“Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release NotesTo Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software.Sun StorageTek Common Array Manager Release Notes, part number 820-5749-12. Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM software includes …Select Sun Storage Common Array Manager Software 6.10, and download the software. For detailed MOS download steps, see the knowledge article “How to Download Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note - Each array should be managed by one CAM management host only.The Sun StorageTek Common Array Manager (CAM) software suite is your main tool for Sun Storage array enclosure management, monitoring, and service capabilities. The software has both a secure browser interface and a command-line interface (CLI). CAM is supported for use with Solaris, Linux and Windows platforms. Viewing Sun Storage …

The Sun StorageTek [TM] Common Array Manager (CAM) has the ability to collect support based configuration and logs for Sun StorEdge [TM], Sun StorageTek [TM], StorageTek …Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).For the Sun Storage J4000 Array Family, refer to the Sun …

The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.0: Enhancements to Auto Service Request (ASR) functionality. Support for Sun StorageTek FLX240, FLX280, and FLX380 Arrays. Sun Storage Common Array Manager Software 6.7.0 Release Notes: PDF: Sun Storage Array Baseline Firmware: PDF: Sun Storage Common Array Manager Array Administration Guide, Version 6.7.0: PDF: Sun Storage Common Array Manager Quick Start Guide: PDF: Sun Storage Common Array Manager Installation and Setup Guide: …Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays.Sun StorageTek Common Array Manager Software Installation Guide, Version 6.5.0: HTML: PDF: Sun StorageTek Array Administration Guide, Version 6.6.0: PDF: Sun StorageTek Common Array Manager User Guide for Open Systems: HTML: PDF: Sun StorageTek Common Array Manager CLI Guide, Version 6.6.0: HTML: PDF: Sun …Common Array Manager May be Solaris forum is not the best choice for asking such question, but I really need help with SunStorage FC array. AFAIK this array can be configured only with CAM software by Sun, but sadly all previously free Metalink downloads are now accessible only as a part of paid support (and I have no idea why we …From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page. The Sun Storage Common Array Manager (CAM) 6.10 Update release is available only for Solaris OS management hosts. Oracle’s Sun Storage Common Array Manager (CAM) 6.10 software that includes the fix for the following CVEs is supported only on Oracle Solaris 10 SPARC and x86 platforms. If you are running the CAM software on Windows or Linux ... Multiple array management<br /> Remote Proxy<br /> The remote proxy agent enables communication, equivalent to in-band management,<br /> from the full management host to the array over an out-of-band-band IP network.<br />Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. Instead customers typically do remote scripting using the remote CLI …This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …

Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, …

SANtricity Storage Manager - Version 10.50 and later Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. The purpose of this document is to provide a description of how to review the details …

vi Sun StorageTek Common Array Manager Software Installation Guide • October 2006 Creating Initiators to Assign to Hosts 61 To Create An Initiator and Assign It To a Host: 61 Using the New Volume Wizard to Create and Map Volumes 62 To Use the New Volume Wizard to Create Volumes 62 About Volumes and the Default Domain or Partitioned …It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …The Sun StorageTek Common Array Manager software is a web-based management software that provides both a browser interface and a command-line interface (CLI) for …This chapter describes performing general administrative tasks applicable to all arrays. It contains the following subsections: “Using the Browser Interface” on page 2 “Administering Storage Arrays” on page 11 “Administering User Accounts” on page 17. 1. Using the Browser Interface Sun StorageTek Common Array Manager 软件发行说明 3 发行文档 以下是 Sun StorageTek Common Array Manager 的相关文档列表。对于文件号码中带 有 nn 后缀的文档,请使用其最新版本。 此外,Common Array Manager 软件还包含有关 CLI 命令的联机帮助和手册页。 Firmware. Firmware delivered with Sun Storage Common Array Manager software can be installed using the Install Firmware Baseline feature. However, moving from one major firmware release to another (6.x to 7.x) requires a utility specific to the array family.The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 5.1.3: Sun Connection (Auto Service Request): registration, telemetry, and automated case generation. Support for 2500 Series Arrays.9. Choose Typical to install the full management software on the data host. 10. Click next to display the Review Selections Screen. The screen should show that the software to be installed is the Full Install. The …

Sun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version … 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Purpose. The purpose of this document is to help troubleshoot the Sun Storage Common Array Manager (CAM) login problem that produces the error:Common Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.Instagram:https://instagram. eng to rotoojay's vero beachnewsmax plus appsge google Select Sun Storage Common Array Manager Software 6.10, and download the software. For detailed MOS download steps, see the knowledge article “How to Download Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note - Each array should be managed by one CAM management host only. badstandard note Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options … us number phone Sun StorageTek Common Array Manager 软件发行说明 3 发行文档 以下是 Sun StorageTek Common Array Manager 的相关文档列表。对于文件号码中带 有 nn 后缀的文档,请使用其最新版本。 此外,Common Array Manager 软件还包含有关 CLI 命令的联机帮助和手册页。 Sun Storage Common Array Manager Installation and Setup Guide Administration, configuration, and monitoring Online help integrated with the software. Customer and field replacement procedures Service Advisor integrated with the software. Reference information for the CLI Sun Storage Common Array Manager CLI Guide sscsman pagesSun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. There are several components of the Sun StorageTek[TM] Common Array Manager (CAM) software : Solaris Web Console(SWC) Browser/Remote sscs interface(BUI/CLI) Fault Management Service(FMS)